INSTRUCTION BOOK
Directional Power Sensor
5010B & 5014
©Copyright 2009 by Bird Electronic Corporation
Instruction Book Part Number 920-5010S Rev. B
Przeglądanie stron 0
1 2 3 4 5 6 ... 26 27

Podsumowanie treści

Strona 1 - Directional Power Sensor

INSTRUCTION BOOKDirectional Power Sensor5010B & 5014©Copyright 2009 by Bird Electronic CorporationInstruction Book Part Number 920-5010S Rev. B

Strona 3 - Safety Symbols

ixTable of ContentsSafety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . 0Safety Symbols. . . . . . . . . . . . . . . . . . . . . . .

Strona 5 - Safety Statements

1Chapter 1 IntroductionDescriptionThe DPS series sensors utilize elements in order to make power measurements. Each element has an arrow on it that re

Strona 6

2In addition, 43 type elements can be used to measure average power in signals with a peak-to-average ratio close to 1, like a CW or FM signals. In th

Strona 7

3Insert the forward element into the forward socket with its arrow pointing in the direction of forward power. Insert the reflected element into the r

Strona 8

42. After centering the contact, bend the contact bar slightly toward the center of the element socket bore, so that the profile of the element contac

Strona 9 - Literature Contents

5Chapter 2 InstallationConnecting the Directional Power Sensor (DPS)1. Do one of the following:z To connect to a Digital Power Meter:z For Models 5010

Strona 10

6z For Models 5014:Connect the Bird DPS to the “Sensor” USB port on the DPM using the sensor cable provided. z To connect to a PC with VPM2 software (

Strona 11 - Table of Contents

7Chapter 3 Specifications5010B SpecificationsSensor Type Thruline two-element line sectionElements5010B5010TSelect two elements from the same series,

Strona 12

0Safety PrecautionsThe following are general safety precautions that are not necessarily related to any specific part or procedure, and do not necessa

Strona 13 - Chapter 1 Introduction

8Power Measurement Uncertainty± 5% of full scale average power (95% c.l.)Peak Power Measurement, 43 Elements only, Forward direction onlyPulse Width,

Strona 14 - Element Orientation

9Mechanical Shock and VibrationIn accordance with MIL-PRF-28800F Class 3CE CE compliant. Refer to DOC for specific standards.Recommended Calibration I

Strona 15

10InterfaceBird Electronic Corp.Solon, Ohio USAModel 5010BDirectional Power SensorOutputInput®ForwardReflectedOutput Input3.5” (90 mm)5” (130 mm)Outpu

Strona 16

115014 SpecificationsSensor Type Thruline two-element line sectionElements APM or 43 series elements. Select two elements from the same series, with R

Strona 17 - Chapter 2 Installation

12Uncertaintyb± 8% of full-scale peak envelope power (95% c.l.)Match MeasurementMatch RangeReturn LossRho (ρ)VSWR0 to 20 dB0.1 to 11.22 to 99.99Uncert

Strona 18

13Temp, Operating –10 to +50 °C (+14 to +122 °F)Temp, Storage –40 to +75 °C (–40 to +167 °F)Humidity, Max 95% (non-condensing)Altitude, Max 3,000 m (1

Strona 20

15Limited WarrantyAll products manufactured by Seller are warranted to be free from defects in material and workmanship for a period of one (1) year,

Strona 21

iSafety SymbolsNote: Calls attention to supplemental information.WARNINGSafety Earth GroundAn uniterruptible earth safety ground must be supplied fro

Strona 22 - ForwardReflected

iiWarning StatementsThe following safety warnings appear in the text where there is danger to operating and maintenance personnel, and are repeated he

Strona 23 - 5014 Specifications

iiiSafety StatementsUSAGEANY USE OF THIS INSTRUMENT IN A MANNER NOT SPECIFIED BY THE MANUFACTURER MAY IMPAIR THE INSTRUMENT’S SAFETY PROTECTION.USOEL

Strona 24

ivSERVICESERVICING INSTRUCTIONS ARE FOR USE BY SERVICE - TRAINED PERSONNEL ONLY. TO AVOID DANGEROUS ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING UNLES

Strona 25

vASSISTENZA TECNICALE ISTRUZIONI RELATIVE ALL’ASSISTENZA SONO PREVISTE ESCLUSIVAMENTE PER IL PERSONALE OPPORTUNAMENTE ADDESTRATO. PER EVITARE PERICOLO

Strona 26

viRF VOLTAGE MAY BE PRESENT IN RF ELEMENT SOCKET - KEEP ELEMENT IN SOCKET DURING OPERATION.DE LA TENSION H.F. PEAT ÊTRE PRÉSENTE DANS LA PRISE DE L&ap

Strona 27 - Limited Warranty

viiAbout This ManualThis manual covers the operating and maintenance instructions for the following models:Changes to this ManualWe have made every ef